Clinical KnowledgeA–Z topicsExams ▾Start free

Clinical Knowledge › Ophthalmology › Basics of ophthalmology

Measurement of intraocular pressure

Intraocular pressure (IOP) reflects the balance between aqueous production by the ciliary body and outflow through the trabecular meshwork and uveoscleral route. Normal IOP is about 10–21 mmHg, with a mean near 15–16 mmHg and a diurnal swing of a few mmHg, usually highest in the early morning. Raised IOP is the main modifiable risk factor for glaucoma, and IOP measurement is essential in glaucoma, red eye, uveitis, trauma and steroid use. Goldmann applanation tonometry (GAT) at the slit lamp, based on the Imbert–Fick principle, is the reference standard: after topical anaesthetic and fluorescein, two semicircular mires are aligned and the dial reading multiplied by 10 gives mmHg. Thin corneas under-read and thick corneas over-read, so central corneal thickness is measured by pachymetry and is itself a risk factor (OHTS). Non-contact (air-puff), rebound, Tono-Pen and Perkins tonometers suit screening, children and bed-bound patients. Tonometry must never be done on a possibly ruptured globe, and prisms must be disinfected or single-use.

Full interactive lesson
Patient case, mechanism, investigations, management, flashcards and exam-style questions.
Open the lesson →

Key facts

Differential diagnosis

ConditionCluesKey test
Ocular hypertensionIOP over 21 mmHg, normal discs and fields, open angleRepeat GAT, pachymetry, OCT, fields
Primary open-angle glaucomaRaised or normal IOP with cupping and field lossFields, OCT RNFL, gonioscopy
Acute angle-closure glaucomaVery high IOP, painful red eye, cloudy cornea, mid-dilated pupilTonometry, gonioscopy of fellow eye
Steroid-induced ocular hypertensionIOP rise 2–6 weeks after starting topical or systemic steroidsSerial IOP, review steroid
Uveitic glaucoma (e.g. herpetic, Posner–Schlossman)Raised IOP with AC cells and KPsSlit lamp, gonioscopy
Artefactually high readingSqueezing, pressure on lids, tight collar, too much fluorescein, thick corneaRepeat with correct technique, pachymetry
Low IOP (hypotony)Penetrating injury, wound leak after surgery, choroidal detachment, severe uveitisSeidel test, B-scan

Exam pearls

IOP is a risk factor, not a diagnosis: glaucoma is diagnosed by the optic disc and field, and a third or more of people with glaucoma have IOP within the normal range at a single visit.
Wide, thick mires mean too much fluorescein and an over-reading; thin mires mean too little and an under-reading.
No correction formula for corneal thickness is reliable; treat thin CCT as an added risk rather than 'correcting' the number.
Steroid responders can develop dangerous IOP rises within weeks of topical or even inhaled and systemic steroids; check IOP in anyone on long-term steroid drops.
Measure IOP at a similar time of day at each visit, or record the time, because diurnal swings can mimic progression.
Digital palpation is only a crude test for a very hard eye; never press on a possibly perforated eye.

Guideline

European Glaucoma Society Terminology and Guidelines (6th edition, 2025), AAO POAG and POAG Suspect PPPs (2025, published 2026) and NICE NG81 (2017, updated 2022)

References

  1. Whitacre MM, Stein R.. Sources of error with use of Goldmann-type tonometers. Surv Ophthalmol 1993.
  2. Cook JA, Botello AP, Elders A, et al.. Systematic review of the agreement of tonometers with Goldmann applanation tonometry. Ophthalmology 2012.
  3. Rödter TH, Knippschild S, Baulig C, Krummenauer F.. Meta-analysis of the concordance of Icare PRO-based rebound and Goldmann applanation tonometry in glaucoma patients. Eur J Ophthalmol 2020.
  4. Kass MA, Heuer DK, Higginbotham EJ, et al.. The Ocular Hypertension Treatment Study: a randomized trial determines that topical ocular hypotensive medication delays or prevents the onset of primary open-angle glaucoma. Arch Ophthalmol 2002.
  5. Gordon MO, Beiser JA, Brandt JD, et al.. The Ocular Hypertension Treatment Study: baseline factors that predict the onset of primary open-angle glaucoma. Arch Ophthalmol 2002.
  6. European Glaucoma Society. Terminology and Guidelines for Glaucoma, 6th edition. European Glaucoma Society 2025.

Related topics

Eye and orbit anatomyVisual pathwayVisual acuity testingVisual field testingPupillary examinationFundoscopySlit-lamp examinationEye movement examinationColour vision testingOCT and fluorescein angio

By Dr Khalid Seidi (B.Sc., M.D.) · MedEd World Clinical Knowledge library. Original teaching content checked against current guidelines (November 2026); confirm the latest local guidance before clinical use. Not a substitute for clinical judgement.