Clinical KnowledgeA–Z topicsExams ▾Start free

Clinical Knowledge › Radiology › Basics of radiology

MRI principles and common sequences (T1, T2, FLAIR, DWI)

Magnetic resonance imaging uses a strong static magnetic field (usually 1.5 or 3 tesla), radiofrequency pulses and switched gradients to map signal from hydrogen nuclei, mainly in water and fat. After excitation, protons recover longitudinal magnetisation (T1 relaxation) and lose transverse coherence (T2 relaxation) at rates that differ between tissues; repetition time (TR) and echo time (TE) choose which property dominates contrast. On T1-weighted images fat, gadolinium, methaemoglobin and protein are bright and fluid is dark; on T2-weighted images fluid and most pathology are bright. FLAIR is a T2-weighted sequence with CSF nulled, ideal for periventricular and cortical lesions. Diffusion-weighted imaging (DWI) with its ADC map shows restricted water movement within minutes of ischaemic stroke and in abscesses and cellular tumours. MRI uses no ionising radiation and has superb soft-tissue contrast, but it is slower and less available than CT, and the magnet demands strict safety screening for implants, foreign bodies and ferromagnetic objects.

Full interactive lesson
Patient case, mechanism, investigations, management, flashcards and exam-style questions.
Open the lesson →
SWI compared with gradient echo
SWI compared with gradient echo Axial MRI comparing sequences: susceptibility-weighted imaging shows small dark microbleeds more clearly than gradient echo. · SBarnes · CC BY-SA 3.0 · Wikimedia Commons

Key facts

Differential diagnosis

ConditionCluesKey test
Acute ischaemic infarctBright DWI, dark ADC, vascular territoryDWI/ADC with MRA or CTA
T2 shine-throughBright DWI and bright ADCCheck ADC map
Cerebral abscessRing enhancement with central restricted diffusionDWI, contrast MRI
Necrotic tumour (glioblastoma, metastasis)Ring enhancement, central fluid without restriction, thick irregular wallDWI, perfusion, spectroscopy
Multiple sclerosis plaqueOvoid periventricular, juxtacortical, infratentorial or cord T2/FLAIR lesions, central vein signFLAIR, contrast for active lesions
Small vessel ischaemic changeConfluent periventricular and deep white matter T2 hyperintensity in older patients with vascular riskFLAIR; clinical context
Haemorrhage at different agesSignal varies with haemoglobin state; blooming on susceptibility imagesT1, T2 and SWI/GRE together

Exam pearls

To tell T1 from T2 quickly, look at CSF or bladder urine: dark on T1, bright on T2; on FLAIR CSF is dark but oedema remains bright.
Always read DWI with the ADC map: true restriction is bright on DWI and dark on ADC.
'Bright on T1' is a short list worth memorising: fat, gadolinium, methaemoglobin, melanin, protein, some calcification, manganese and slow flow.
Fat suppression (STIR or spectral fat-saturation) turns a T2 image into an oedema map: bone marrow oedema, occult fractures and inflammation light up.
MRI without gadolinium is considered safe in any trimester when clinically indicated; gadolinium crosses the placenta and is avoided unless essential.
A patient who arrests in the scanner must be taken out of the magnet room before resuscitation: the magnet is always on.

Guideline

ACR Manual on MR Safety (2024) and MHRA MRI equipment safety guidance (2021), with the ACR-NKF consensus on gadolinium-based contrast in kidney disease (2021) and the 2024 McDonald criteria (published 2025)

References

  1. Bushberg JT, Seibert JA, Leidholdt EM Jr, Boone JM.. The Essential Physics of Medical Imaging. 2020.
  2. American College of Radiology. ACR Manual on MR Safety. ACR 2024.
  3. Medicines and Healthcare products Regulatory Agency. Safety guidelines for magnetic resonance imaging equipment in clinical use. MHRA 2021.
  4. Weinreb JC, Rodby RA, Yee J, et al.. Use of intravenous gadolinium-based contrast media in patients with kidney disease: consensus statements from the American College of Radiology and the National Kidney Foundation. Radiology 2021.
  5. Kanal E, Barkovich AJ, Bell C, et al.. ACR guidance document on MR safe practices: 2013. J Magn Reson Imaging 2013.
  6. American College of Radiology Committee on Drugs and Contrast Media. ACR Manual on Contrast Media. ACR 2024.

Related topics

X-ray image formationProjections and adequacyCT, HU and windowingUltrasound and DopplerChoosing imaging testsRequests and reportsSystematic interpretation

By Dr Khalid Seidi (B.Sc., M.D.) · MedEd World Clinical Knowledge library. Original teaching content checked against current guidelines (November 2026); confirm the latest local guidance before clinical use. Not a substitute for clinical judgement.