Skin grafts and flaps
Skin grafts and flaps are the two basic tools for closing wounds that cannot be closed directly. A graft is tissue moved without its blood supply, so it survives only if the recipient bed is vascular: it lives on plasma for the first 48 hours (imbibition), then vessels align (inosculation) and grow in (revascularisation) over about 5 days. Split-thickness grafts take easily and cover large areas but contract and look shiny; full-thickness grafts match colour and contract less but need a better bed and a small defect. A flap carries its own blood supply and can cover bone, tendon, implants or irradiated tissue: it may be random or axial, local, pedicled or free (vessels re-joined under the microscope). Choice follows the reconstructive ladder or elevator. Haematoma or seroma, shear and infection are the main causes of graft loss. Free flaps need hourly checks of colour, capillary refill, temperature and Doppler in the first 24–48 hours, because a congested or ischaemic flap can often be saved by urgent return to theatre.
Patient case, mechanism, investigations, management, flashcards and exam-style questions.Open the lesson →

Key facts
- Graft = no blood supply of its own; flap = carries its own blood supply
- Graft take: plasmatic imbibition (0–48 h), inosculation (about 48–72 h), revascularisation (by about day 5)
- Commonest cause of graft failure: haematoma or seroma under the graft; also shear, infection and a poor bed
- Grafts will not take on bare cortical bone, tendon without paratenon, cartilage without perichondrium, or exposed implants: these need a flap
- Split-thickness grafts: more primary take, more secondary contraction; full-thickness grafts: better colour and texture, less secondary contraction
- Beta-haemolytic streptococci (Streptococcus pyogenes) can destroy a graft even in small numbers
- Venous congestion: purple, swollen, brisk dark bleeding; arterial insufficiency: pale, cool, no capillary refill
- Open fracture standards: definitive soft-tissue cover within 72 hours of injury if not achieved at the first debridement
Differential diagnosis
| Condition | Clues | Key test |
|---|---|---|
| Healing by secondary intention | Small, shallow or concave wounds (e.g. fingertip, medial canthus) | Dressings; no donor site |
| Direct (primary) closure | Small defect with lax surrounding skin | Tension-free closure along relaxed skin tension lines |
| Negative pressure wound therapy | Bridging to definitive closure; promotes granulation | Temporary; not a substitute for flap over bone |
| Dermal substitute (e.g. collagen–glycosaminoglycan matrix) | Large burns or exposed tendon in selected cases | Requires later thin split-thickness graft |
| Split-thickness skin graft | Large, well-vascularised bed | Donor site heals from adnexal remnants |
| Full-thickness skin graft | Small facial or hand defect needing colour match | Donor site closed directly |
| Local or pedicled flap | Exposed structures near a mobile skin reservoir | Random or axial pattern |
| Free flap | Large or complex defects, distal lower limb, head and neck | Microvascular anastomosis |
Exam pearls
Guideline
BOA/BAPRAS Standards for the Management of Open Fractures (2020) with BOAST Open fractures (2017), and ISBI Practice Guidelines for Burn Care (2016; part 2, 2018)
References
- Eccles S, Handley B, Khan U, McFadyen I, Nanchahal J, Nayagam S, eds.. Standards for the Management of Open Fractures. Oxford University Press 2020.
- British Orthopaedic Association. BOAST: Open fractures. British Orthopaedic Association Standards for Trauma 2017.
- ISBI Practice Guidelines Committee. ISBI practice guidelines for burn care. Burns 2016.
- Alsaif A, Karam M, Hayre A, et al.. Full thickness skin graft versus split thickness skin graft in paediatric patients with hand burns: systematic review and meta-analysis. Burns 2023.
- Moors JJE, Xu Z, Xie K, et al.. Full-thickness skin graft versus split-thickness skin graft for fasciocutaneous radial forearm free flap donor site closure: a systematic review and meta-analysis. Syst Rev 2025.
- Klifto KM, Milek D, Gurno CF, et al.. Comparison of arterial and venous implantable Doppler postoperative monitoring of free flaps: systematic review and meta-analysis of diagnostic test accuracy. Microsurgery 2020.
Related topics
By Dr Khalid Seidi (B.Sc., M.D.) · MedEd World Clinical Knowledge library. Original teaching content checked against current guidelines (November 2026); confirm the latest local guidance before clinical use. Not a substitute for clinical judgement.