Clinical Knowledge › Ear, nose and throat › Basics of ear, nose and throat
Tuning fork tests (Rinne and Weber)
Tuning fork tests are quick bedside tests that help decide whether a hearing loss is conductive (outer or middle ear) or sensorineural (cochlea or nerve). A 512 Hz fork is used because lower frequencies are felt as vibration and higher ones fade too fast. In the Rinne test, air conduction (fork beside the ear canal) is compared with bone conduction (fork base on the mastoid): normally air conduction is louder (Rinne positive). A negative Rinne (bone louder than air) indicates a conductive loss of roughly 20–30 dB or more on that side. In the Weber test the fork is placed in the midline (forehead, vertex or upper incisors): sound lateralises to the ear with a conductive loss, or away from the ear with a sensorineural loss. Combined, the two tests localise the problem. The key trap is the false-negative Rinne in a dead ear, where bone-conducted sound is heard by the other cochlea. Tuning forks are especially useful in suspected sudden sensorineural hearing loss, where they separate it from wax or effusion and prompt same-day referral, but they do not replace pure tone audiometry.
Patient case, mechanism, investigations, management, flashcards and exam-style questions.Open the lesson →
Key facts
- Use a 512 Hz fork, struck on a rubber pad, knee or elbow about two-thirds up the tines, never on a hard surface (overtones)
- Rinne: compare air conduction (tines about 2 cm from the canal opening) with bone conduction (base on mastoid behind the ear); AC louder than BC is 'Rinne positive' (normal or sensorineural)
- Rinne negative (BC louder than AC) means a conductive loss with an air–bone gap usually of at least about 20–30 dB at 512 Hz
- Weber: fork in the midline; lateralises to the conductive-loss ear or to the better cochlea when there is a sensorineural loss
- Conductive right loss: Rinne negative right, Weber to the right. Sensorineural right loss: Rinne positive both sides, Weber to the left
- False-negative Rinne: in a severe unilateral sensorineural loss, bone conduction is heard by the other cochlea; Weber goes to the good ear, which exposes the trap
- Systematic review: sensitivity of a 512 Hz Rinne for conductive loss ranges widely (about 16–87%) with specificity of about 55–100%; small conductive losses are missed
- In sudden hearing loss, tuning forks quickly separate sudden sensorineural loss (needs same-day referral and steroids) from wax or effusion
Differential diagnosis
| Condition | Clues | Key test |
|---|---|---|
| Wax impaction | Rinne negative and Weber to the blocked ear; wax on otoscopy | Otoscopy; recheck after removal |
| Otitis media with effusion | Conductive pattern with dull drum | Tympanometry type B |
| Otosclerosis | Conductive pattern with a normal drum; family history; young adult | Audiogram (Carhart notch), tympanometry As, absent stapedial reflexes |
| Sudden sensorineural hearing loss | Rinne positive, Weber to the good ear; onset within 72 hours | Urgent audiogram |
| Vestibular schwannoma | Unilateral SNHL pattern, unilateral tinnitus | Audiogram and MRI internal auditory meatus |
| Presbycusis | Bilateral SNHL; Rinne positive both, Weber central | Audiogram |
| Dead ear (profound unilateral SNHL) | Rinne 'negative' on the bad side but Weber to the good ear | Rinne with masking; audiogram |
Exam pearls
Guideline
AAO-HNSF Sudden Hearing Loss Update (2019) with NICE NG98 Hearing loss in adults (2018) and AAO-HNSF Age-Related Hearing Loss (2024)
References
- Watkinson JC, Clarke RW, eds.. Scott-Brown's Otorhinolaryngology and Head and Neck Surgery. CRC Press 2018.
- Flint PW, Francis HW, Haughey BH, et al., eds.. Cummings Otolaryngology: Head and Neck Surgery. Elsevier 2021.
- Bagai A, Thavendiranathan P, Detsky AS. Does this patient have hearing impairment?. JAMA 2006.
- Kelly EA, Li B, Adams ME. Diagnostic Accuracy of Tuning Fork Tests for Hearing Loss: A Systematic Review. Otolaryngol Head Neck Surg 2018.
- National Institute for Health and Care Excellence (NICE). Hearing loss in adults: assessment and management (NG98). NICE guideline NG98 2018.
- Chandrasekhar SS, Tsai Do BS, Schwartz SR, et al.. Clinical Practice Guideline: Sudden Hearing Loss (Update). Otolaryngol Head Neck Surg 2019.
Related topics
By Dr Khalid Seidi (B.Sc., M.D.) · MedEd World Clinical Knowledge library. Original teaching content checked against current guidelines (November 2026); confirm the latest local guidance before clinical use. Not a substitute for clinical judgement.