Clinical KnowledgeA–Z topicsExams ▾Start free

Clinical Knowledge › Anaesthesiology › General anaesthesia

Intraoperative ventilation strategies

Intraoperative ventilation aims to maintain oxygenation and normocapnia while minimising lung injury and postoperative pulmonary complications (PPCs), which affect about 5–10% of surgical patients and up to a third of high-risk patients. General anaesthesia reduces functional residual capacity, and atelectasis develops within minutes in most patients, worsened by high inspired oxygen, obesity, pneumoperitoneum and the head-down position. Lung-protective ventilation uses a tidal volume of 6–8 mL/kg predicted body weight, PEEP of about 5 cmH2O adjusted to the patient, the lowest driving pressure achievable, and the lowest FiO2 that keeps SpO2 at a safe level. IMPROVE (2013) showed fewer complications with protective ventilation than with large tidal volumes and no PEEP, whereas PROVHILO, PROBESE and DESIGNATION (2025) found that routinely high PEEP with recruitment manoeuvres gave no benefit and more hypotension. Special strategies apply for obesity, laparoscopy, obstructive lung disease, one-lung ventilation and patients with ARDS.

Full interactive lesson
Patient case, mechanism, investigations, management, flashcards and exam-style questions.
Open the lesson →

Key facts

Differential diagnosis

ConditionCluesKey test
AtelectasisGradual fall in SpO2 and compliance, especially after induction, obesity or high FiO2Response to PEEP and recruitment; lung ultrasound B-lines and consolidation
Endobronchial intubationSudden desaturation, high airway pressure, unilateral breath sounds after position changeCheck tube depth, auscultate, fibreoptic or chest radiograph
BronchospasmHigh peak pressure, shark-fin capnogram, wheezeAuscultation; consider anaphylaxis
Dynamic hyperinflation (auto-PEEP)Hypotension and rising pressures in COPD or asthma with incomplete expirationExpiratory flow not reaching zero; expiratory hold; disconnect circuit briefly
PneumothoraxHigh pressures, hypoxaemia, hypotension, unilateral reduced breath soundsLung ultrasound, chest radiograph; needle decompression if tension
Pulmonary oedema or aspirationFalling compliance, crackles, pink frothy or gastric material in tubeChest radiograph, suction, echocardiography
Excessive pneumoperitoneum or TrendelenburgRising plateau pressure during laparoscopyCheck insufflation pressure and position

Exam pearls

Tidal volume follows height and sex, not weight: a 160 cm woman weighing 120 kg has a predicted body weight of about 53 kg, so 6–8 mL/kg is about 320–420 mL.
The lowest driving pressure, not the highest PEEP, is the more useful target: if increasing PEEP raises driving pressure, it is overdistending, not recruiting.
Peak pressure reflects airway resistance plus compliance; plateau pressure (inspiratory hold) reflects compliance alone. High peak with normal plateau means airway or tube problem.
Absorption atelectasis follows 100% oxygen: alveoli behind closed airways lose their oxygen to blood with no nitrogen left to hold them open.
In bronchospasm or COPD, if blood pressure falls after starting ventilation, disconnect the circuit for 20–30 seconds: hyperinflation is impairing venous return.
Laparoscopic pneumoperitoneum raises plateau pressure largely by stiffening the chest wall; transpulmonary pressure may be less than the airway pressure suggests.

Guideline

International expert panel consensus recommendations on lung-protective ventilation for the surgical patient (2019), informed by IMPROVE (2013), PROVHILO (2014), PROBESE (2019) and DESIGNATION (2025)

References

  1. Young CC, Harris EM, Vacchiano C, et al.. Lung-protective ventilation for the surgical patient: international expert panel-based consensus recommendations. Br J Anaesth 2019.
  2. Futier E, Constantin JM, Paugam-Burtz C, et al.. A trial of intraoperative low-tidal-volume ventilation in abdominal surgery. N Engl J Med 2013.
  3. PROVE Network Investigators; Hemmes SN, Gama de Abreu M, Pelosi P, Schultz MJ.. High versus low positive end-expiratory pressure during general anaesthesia for open abdominal surgery (PROVHILO trial): a multicentre randomised controlled trial. Lancet 2014.
  4. Writing Committee for the PROBESE Collaborative Group; Bluth T, Serpa Neto A, et al.. Effect of intraoperative high positive end-expiratory pressure (PEEP) with recruitment maneuvers vs low PEEP on postoperative pulmonary complications in obese patients: a randomized clinical trial. JAMA 2019.
  5. Neto AS, Hemmes SN, Barbas CS, et al.. Association between driving pressure and development of postoperative pulmonary complications in patients undergoing mechanical ventilation for general anaesthesia: a meta-analysis of individual patient data. Lancet Respir Med 2016.
  6. Writing and Steering Committees for the DESIGNATION Investigators; Dorland G, Gama de Abreu M, et al.. Intraoperative driving pressure-guided high PEEP vs standard low PEEP for postoperative pulmonary complications. JAMA 2026.

Related topics

Components and stages of GAInduction of anaesthesiaVolatile vs TIVAIntraoperative monitoringCapnographyDepth monitoring and AAGAPerioperative hypothermiaPositioning injuriesPACU / recovery room

By Dr Khalid Seidi (B.Sc., M.D.) · MedEd World Clinical Knowledge library. Original teaching content checked against current guidelines (November 2026); confirm the latest local guidance before clinical use. Not a substitute for clinical judgement.