Clinical KnowledgeA–Z topicsExams ▾Start free

Clinical Knowledge › Anaesthesiology › Regional and local anaesthesia

Ultrasound guidance in regional anaesthesia

Ultrasound guidance has become the standard way to perform most peripheral nerve and fascial plane blocks, replacing blind landmark and paraesthesia techniques and largely supplementing nerve stimulation. A high-frequency linear probe (8–15 MHz) images superficial nerves, while a low-frequency curvilinear probe (2–5 MHz) is needed for deep structures such as the sciatic nerve in an obese patient. Nerves appear as honeycomb (fascicular) structures that are hyperechoic in the limbs and more hypoechoic in the neck; vessels are anechoic and compressible, with Doppler used to confirm arteries. Seeing the needle tip, the nerve and the spread of injectate shortens onset, reduces the volume needed, improves success and reduces vascular puncture and local anaesthetic systemic toxicity, which registry data suggest falls by around two-thirds. Ultrasound does not abolish nerve injury or toxicity, so dose limits, aspiration, injection pressure awareness, standardised nomenclature, training and credentialling remain essential.

Full interactive lesson
Patient case, mechanism, investigations, management, flashcards and exam-style questions.
Open the lesson →
Ultrasound-guided injection with needle visible
Ultrasound-guided injection with needle visible Paired scans of the buttock before (A) and during (B) an ultrasound-guided piriformis injection; the needle is seen as a bright line, with the sciatic nerve (sn) deep to the muscle. · Elsawy AGS et al. · CC BY 4.0 · Wikimedia Commons

Key facts

Differential diagnosis

ConditionCluesKey test
Tendon mistaken for nerveFibrillar rather than honeycomb pattern; moves and changes shape with joint movementScan dynamically along its course; tendons attach to bone and muscle
Vein mistaken for nerve or fascial planeAnechoic, compressible, may show flow with DopplerCompression and colour Doppler
Artery adjacent to the targetPulsatile, non-compressible, bright Doppler signalColour or power Doppler before needling
Lymph node mistaken for nerveOval with hilum, in clusters, no continuity along a nerve pathTrace the structure in long axis
Intramuscular septum mistaken for a nerveLinear hyperechoic line without fasciclesFollow proximally and distally; no honeycomb appearance
Needle shaft mistaken for the tipOut-of-plane imaging with an apparent bright dot proximal to the real tipKeep the needle in plane; hydrolocate with 0.5–1 mL
Pleura mistaken for a fascial planeBright sliding line with lung sliding and B-linesIdentify ribs and lung sliding before any chest wall block
Anisotropy artefactNerve disappears when the probe angle changesTilt the probe to restore the perpendicular beam

Exam pearls

If you cannot see the needle tip, stop advancing: move the probe to find the tip rather than pushing the needle to find the image.
No visible spread of injectate means the tip is not where you think it is: intravascular, intraneural or outside the field.
Scan before you prepare: a pre-procedure scan identifies anomalous vessels, scarring and the depth to pleura or peritoneum.
Ultrasound shows anatomy, not safety: dose limits, lipid emulsion availability and monitoring are unchanged.
Nerves in the neck (roots and trunks) tend to look hypoechoic, while limb nerves look more hyperechoic as connective tissue increases distally.
Use the standardised block names from the ASRA–ESRA consensus in notes and handovers so colleagues know exactly what was done.

Guideline

ASRA-ESRA recommendations for education and training in ultrasound-guided regional anaesthesia (2009, with later society curricula), ASRA-ESRA Delphi consensus on block nomenclature (2021), ASRA Practice Advisory on neurological complications (2015) and Association of Anaesthetists standards of monitoring (2021)

References

  1. Sites BD, Chan VW, Neal JM, et al.. The American Society of Regional Anesthesia and Pain Medicine and the European Society of Regional Anaesthesia and Pain Therapy Joint Committee recommendations for education and training in ultrasound-guided regional anesthesia. Reg Anesth Pain Med 2009.
  2. Klein AA, Meek T, Allcock E, et al.. Recommendations for standards of monitoring during anaesthesia and recovery 2021: Guideline from the Association of Anaesthetists. Anaesthesia 2021.
  3. El-Boghdadly K, Wolmarans M, Stengel AD, et al.. Standardizing nomenclature in regional anesthesia: an ASRA-ESRA Delphi consensus study of abdominal wall, paraspinal, and chest wall blocks. Reg Anesth Pain Med 2021.
  4. Neal JM, Barrington MJ, Brull R, et al.. The Second ASRA Practice Advisory on Neurologic Complications Associated With Regional Anesthesia and Pain Medicine: Executive Summary 2015. Reg Anesth Pain Med 2015.
  5. Lewis SR, Price A, Walker KJ, et al.. Ultrasound guidance for upper and lower limb blocks. Cochrane Database Syst Rev 2015.
  6. Barrington MJ, Kluger R.. Ultrasound guidance reduces the risk of local anesthetic systemic toxicity following peripheral nerve blockade. Reg Anesth Pain Med 2013.

Related topics

Spinal anaesthesiaEpidural anaesthesiaHigh and total spinalPost-dural puncture headacheEpidural haematoma/abscessPeripheral nerve blocksInfiltration + field blockBier block (IVRA)LAST

By Dr Khalid Seidi (B.Sc., M.D.) · MedEd World Clinical Knowledge library. Original teaching content checked against current guidelines (November 2026); confirm the latest local guidance before clinical use. Not a substitute for clinical judgement.